Chemical Engineering MCQs designed for job test and interview preparation, particularly for fresh graduates, students, and candidates appearing in competitive exams. These multiple-choice questions cover important topics such as the fundamentals of chemical engineering, chemical processes, chemical reactions, process control, and instrumentation, along with other key concepts in the field.

Identify an unbounded input from inputs whose transfer functions are given below______________?
A 1
B 1/S
C 1/S2
D 1/(S2 + 1)
Correct Answer: 1
The transfer function of a first order system is______________?
A 1/(Ts + 1)
B 1/Ts
C s/(Ts + 1)
D None of these
Correct Answer: 1/(Ts + 1)
Find the ultimate gain and frequency for a proportional controller in the case of a process having the transfer function Gp(s) = 1/(4s + 1)(2s + 1)(s + 1) ?
A w = 1/√14, Kc = 45/7 √14
B w = √(7/6), Kc = 46/3
C w = 1, Kc = 13
D w = √(7/8), Kc = 45/4
Correct Answer: w = √(7/6), Kc = 46/3
Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?
A Filling nitrogen under pressure in the stem
B Increasing the diameter of the tube
C Using steel tube in place of glass tube
D Accounting for the tube expansion
Correct Answer: Filling nitrogen under pressure in the stem
The initial value (t = 0) of the unit step response of the transfer function [(s + 1)/(2s + 1)] is__________________?
A 0
B ½
C 1
D 2
Correct Answer: ½
Stabilising time for the controllers is the time required for the response to reach _____________ percent of its ultimate value?
A 63.2
B 87.5
C 95
D 100
Correct Answer: 95
Thermistors are made of__________________?
A Ultra pure metals
B Metal oxides
C Iron-copper alloys
D Nickel-chromium alloys
Correct Answer: Metal oxides
A pyranometer is an instrument used for measuring the___________________?
A Beam radiation
B Global radiation
C Bright sunshine period
D None of these
Correct Answer: Global radiation
The transfer function for an ideal proportional plus reset controller (reset time T) is_______________?
A Kc[1 + (1/TS)]
B Kc(1 + TS)
C Kc/(1 + TS)
D Kc/[1 + (s/T)]
Correct Answer: Kc[1 + (1/TS)]
Radiation thermometer cannot measure the temperature ___________________?
A Inside a pressure vessel
B Of an object without coming in contact with it
C Of liquid oxygen
D Of moving objects at high temperature
Correct Answer: Of liquid oxygen